64 TECHNISCHER ANHANG NEXUS 120 DC SOUNDER SOUNDER BEACON Signalart Signal Beschreibung Verwendungszweck Zweites Signal DIP Schalter S1 S2 Schalldruck dBA 1m 24V DC Durchschn Stromaufn mA Avg 24V DC 1 970Hz BS5839 1 2002 18 O O O O O O 118 0 55 2 800Hz 970Hz 2Hz BS5839 1 2002 1 O O O O O I 120 0 50 3 800Hz 970Hz 1Hz BS5839 1 2002 1 O O O O I O 120 0 50 4 970Hz 1s OFF 1s ON Apollo Fire Systems Alert Tone BS5839 1 2002 1 O O O O I I 118 0 27 5 970Hz 0 5s 630Hz 0 5s Apollo Fire Systems Evacuate Tone BS5839 1 2002 1 O O O I O O 118 0 51 6 554Hz 0 1s 440Hz 0 4s France AFNOR NF S 32 001 1 O O O I O I 118 0 33 7 500 1200Hz 3 5s 0 5sOFF Netherlands NEN2575 2000 Dutch SlowWhoop 1 O O O I I O 120 0 45 8 420Hz 0 625s ON 0 625s OFF Australia AS1670 Alert tone 1 O O O I I I 115 0 17 9 500 1200Hz 0 5s 0 5s OFF x 3 1 5s OFF Australia AS1670 Evacuation tone 1 O O I O O O 119 0 22 10 550Hz 440Hz 0 5Hz 19 O O I O O I 118 0 34 11 970Hz 0 5s ON 0 5s OFF x 3 1 5s OFF ISO 8201 Low tone 1 O O I O I O 118 0 21 12 2850Hz 0 5s ON 0 5s OFF x 3 1 5s OFF ISO 8201 High tone 1 O O I O I I 110 0 19 13 1200Hz 500Hz 1Hz DIN 33 404 1 O O I I O O 119 0 50 14 400Hz 18 O O I I O I 114 0 36 15 550Hz 0 7s 1000Hz 0 33s 1 O O I I I O 120 0 39 16 1500Hz 2700Hz 3Hz Vandal Alarm 1 O O I I I I 118 0 47 17 Simulated Bell 1 O I O O O O 115 0 32 18 840Hz 1 O I O O O I 119 0 51 19 660Hz 10 O I O O I O 114 0 51 20 660Hz 1 8s ON 1 8s OFF 19 O I O O I I 114 0 26 21 660Hz 0 15s ON 0 15s OFF 19 O I O I O O 113 0 27 22 510Hz 0 25s 610Hz 0 25s 1 O I O I O I 115 0 44 23 800 1000Hz 0 5s each 1Hz 1 O I O I I O 120 0 51 24 250Hz 1200Hz 12Hz 1 O I O I I I 114 0 52 25 500Hz 1200Hz 0 33Hz 1 O I I O O O 119 0 51 26 2400Hz 2900Hz 9Hz 1 O I I O O I 113 0 45 27 2400Hz 2900Hz 3Hz 1 O I I O I O 113 0 45 28 800Hz 970Hz 100Hz 1 O I I O I I 120 0 50 29 800Hz 970Hz 9Hz 1 O I I I O O 120 0 50 30 800Hz 970Hz 3Hz 1 O I I I O I 120 0 50 31 800Hz 0 25s ON 1s OFF 1 O I I I I O 119 0 12 32 500Hz 1200Hz 3 75s 0 25s OFF AS2220 1 O I I I I I 119 0 48 33 340Hz 1 I O O O O O 114 0 33 34 1000Hz 18 I O O O O I 116 0 51 35 1400Hz 1600Hz 1s 1600Hz 1400Hz 0 5s NF 48 265 1 I O O O I O 120 0 50 36 660Hz 6 5s ON 13s OFF 19 I O O O I I 114 0 18 37 1000Hz 2000Hz 1s each 1 I O O I O O 117 0 49 38 720Hz 0 7s ON 0 3s OFF 1 I O O I O I 119 0 37 39 970Hz 0 25s ON OFF 1 I O O I I O 118 0 27 40 2800Hz 1s ON OFF 1 I O O I I I 110 0 24 41 2800Hz 0 25s ON OFF 1 I O I O O O 110 0 23 42 2400 2900 2Hz 1 I O I O O I 113 0 44 43 Chime 554Hz 440Hz Single shot ding dong 1 I O I O I O 115 0 28 44 Chime 554Hz 440Hz Repeating ding dong 1 I O I O I I 118 0 28 45 Chime 970Hz 800Hz Single shot ding dong 1 I O I I O O 116 0 28 46 Chime 970Hz 800Hz Repeating ding dong 1 I O I I O I 116 0 28 47 Hooter Repeating 1 I O I I I O 114 0 22 48 Gentle alarm Tone 2 rises slowly to full volume over 30s 1 I O I I I I 120 0 50 49 Time Out Alarm As Tone 2 cuts off after 10 mins 1 I I O O O O 120 0 50 50 Time Out Alarm As Tone 2 cuts off after 2 mins 1 I I O O O I 120 0 50 51 750Hz 0 33s ON 0 51s OFF 1 I I O O I O 119 0 15 52 750Hz 0 51s ON 0 33s OFF 1 I I O O I I 118 0 32 53 550Hz 0 33s 1000Hz 0 7s 1 I I O I O O 117 0 46 54 600Hz 900Hz 0 9s 1 I I O I O I 119 0 50 55 660Hz 680Hz 0 9s 1 I I O I I O 116 0 49 56 670Hz 725Hz 0 9s 1 I I O I I I 119 0 50 57 920Hz 750Hz 0 9s 1 I I I O O O 120 0 51 58 700Hz 900Hz 0 3s 0 6s OFF 1 I I I O O I 119 0 19 59 900Hz 760Hz 0 6s 0 3s OFF 1 I I I O I O 120 0 35 60 750Hz 18 I I I O I I 118 0 49 61 Power Only Use with Stage 3 control for manual intermittent chime triggering 43 I I I I O O 62 Power Only Use with Stage 3 control for manual intermittent chime triggering 43 I I I I O I 63 Power Only Use with Stage 3 control for manual intermittent horn triggering 47 I I I I I O

Vorschau Handbuch der Signalgeber - Einfach normgerecht alarmieren Seite 64
Hinweis: Dies ist eine maschinenlesbare No-Flash Ansicht.
Klicken Sie hier um zur Online-Version zu gelangen.