TECHNISCHER ANHANG 63 NEXUS 110 DC SOUNDER SOUNDER BEACON Signalart Signal Beschreibung Verwendungszweck Zweites Signal DIP Schalter S1 S2 Schalldruck dBA 1m 24V DC Durchschn Stromaufn mA Avg 24V DC 1 970Hz BS5839 1 2002 18 O O O O O O 110 45 2 800Hz 970Hz 2Hz BS5839 1 2002 1 O O O O O I 110 44 3 800Hz 970Hz 1Hz BS5839 1 2002 1 O O O O I O 110 43 4 970Hz 1s OFF 1s ON Apollo Fire Systems Alert Tone BS5839 1 2002 1 O O O O I I 110 25 5 970Hz 0 5s 630Hz 0 5s Apollo Fire Systems Evacuate Tone BS5839 1 2002 1 O O O I O O 110 39 6 554Hz 0 1s 440Hz 0 4s France AFNOR NF S 32 001 1 O O O I O I 107 24 7 500 1200Hz 3 5s 0 5sOFF Netherlands NEN2575 2000 Dutch SlowWhoop 1 O O O I I O 110 28 8 420Hz 0 625s ON 0 625s OFF Australia AS1670 Alert tone 1 O O O I I I 105 9 9 500 1200Hz 0 5s 0 5s OFF x 3 1 5s OFF Australia AS1670 Evacuation tone 1 O O I O O O 110 13 10 550Hz 440Hz 0 5Hz 19 O O I O O I 107 26 11 970Hz 0 5s ON 0 5s OFF x 3 1 5s OFF ISO 8201 Low tone 1 O O I O I O 110 19 12 2850Hz 0 5s ON 0 5s OFF x 3 1 5s OFF ISO 8201 High tone 1 O O I O I I 112 16 13 1200Hz 500Hz 1Hz DIN 33 404 1 O O I I O O 110 34 14 400Hz 18 O O I I O I 105 21 15 550Hz 0 7s 1000Hz 0 33s 1 O O I I I O 111 33 16 1500Hz 2700Hz 3Hz Vandal Alarm 1 O O I I I I 116 46 17 Simulated Bell 1 O I O O O O 112 26 18 840Hz 1 O I O O O I 113 34 19 660Hz 10 O I O O I O 109 31 20 660Hz 1 8s ON 1 8s OFF 19 O I O O I I 108 16 21 660Hz 0 15s ON 0 15s OFF 19 O I O I O O 107 17 22 510Hz 0 25s 610Hz 0 25s 1 O I O I O I 107 28 23 800 1000Hz 0 5s each 1Hz 1 O I O I I O 111 44 24 250Hz 1200Hz 12Hz 1 O I O I I I 105 24 25 500Hz 1200Hz 0 33Hz 1 O I I O O O 110 31 26 2400Hz 2900Hz 9Hz 1 O I I O O I 116 45 27 2400Hz 2900Hz 3Hz 1 O I I O I O 116 45 28 800Hz 970Hz 100Hz 1 O I I O I I 110 42 29 800Hz 970Hz 9Hz 1 O I I I O O 110 43 30 800Hz 970Hz 3Hz 1 O I I I O I 110 43 31 800Hz 0 25s ON 1s OFF 1 O I I I I O 108 10 32 500Hz 1200Hz 3 75s 0 25s OFF AS2220 1 O I I I I I 110 29 33 340Hz 1 I O O O O O 106 18 34 1000Hz 18 I O O O O I 111 47 35 1400Hz 1600Hz 1s 1600Hz 1400Hz 0 5s NF 48 265 1 I O O O I O 110 44 36 660Hz 6 5s ON 13s OFF 19 I O O O I I 108 31 37 1000Hz 2000Hz 1s each 1 I O O I O O 113 41 38 720Hz 0 7s ON 0 3s OFF 1 I O O I O I 106 26 39 970Hz 0 25s ON OFF 1 I O O I I O 110 25 40 2800Hz 1s ON OFF 1 I O O I I I 113 22 41 2800Hz 0 25s ON OFF 1 I O I O O O 113 21 42 2400 2900 2Hz 1 I O I O O I 115 43 43 Chime 554Hz 440Hz Single shot ding dong 1 I O I O I O 104 15 44 Chime 554Hz 440Hz Repeating ding dong 1 I O I O I I 107 15 45 Chime 970Hz 800Hz Single shot ding dong 1 I O I I O O 106 36 46 Chime 970Hz 800Hz Repeating ding dong 1 I O I I O I 106 36 47 Hooter Repeating 1 I O I I I O 107 13 48 Gentle alarm Tone 2 rises slowly to full volume over 30s 1 I O I I I I 109 44 49 Time Out Alarm As Tone 2 cuts off after 10 mins 1 I I O O O O 109 44 50 Time Out Alarm As Tone 2 cuts off after 2 mins 1 I I O O O I 109 44 51 750Hz 0 33s ON 0 51s OFF 1 I I O O I O 106 12 52 750Hz 0 51s ON 0 33s OFF 1 I I O O I I 107 25 53 550Hz 0 33s 1000Hz 0 7s 1 I I O I O O 111 41 54 600Hz 900Hz 0 9s 1 I I O I O I 109 37 55 660Hz 680Hz 0 9s 1 I I O I I O 105 33 56 670Hz 725Hz 0 9s 1 I I O I I I 107 33 57 920Hz 750Hz 0 9s 1 I I I O O O 110 41 58 700Hz 900Hz 0 3s 0 6s OFF 1 I I I O O I 109 15 59 900Hz 760Hz 0 6s 0 3s OFF 1 I I I O I O 110 28 60 750Hz 18 I I I O I I 107 39 61 Power Only Use with Stage 3 control for manual intermittent chime triggering 43 I I I I O O 62 Power Only Use with Stage 3 control for manual intermittent chime triggering 43 I I I I O I 63 Power Only Use with Stage 3 control for manual intermittent horn triggering 47 I I I I I O

Vorschau Handbuch der Signalgeber - Einfach normgerecht alarmieren Seite 63
Hinweis: Dies ist eine maschinenlesbare No-Flash Ansicht.
Klicken Sie hier um zur Online-Version zu gelangen.