62 TECHNISCHER ANHANG NEXUS 105 DC SOUNDER SOUNDER BEACON Signalart Signal Beschreibung Verwendungszweck Zweites Signal DIP Schalter S1 S2 Schalldruck dBA 1m 24V DC Durchschn Stromaufn mA Avg 24V DC 1 970Hz BS5839 1 2002 18 O O O O O O 105 31 2 800Hz 970Hz 2Hz BS5839 1 2002 1 O O O O O I 105 28 3 800Hz 970Hz 1Hz BS5839 1 2002 1 O O O O I O 104 25 4 970Hz 1s OFF 1s ON Apollo Fire Systems Alert Tone BS5839 1 2002 1 O O O O I I 105 17 5 970Hz 0 5s 630Hz 0 5s Apollo Fire Systems Evacuate Tone BS5839 1 2002 1 O O O I O O 105 27 6 554Hz 0 1s 440Hz 0 4s France AFNOR NF S 32 001 1 O O O I O I 103 20 7 500 1200Hz 3 5s 0 5sOFF Netherlands NEN2575 2000 Dutch SlowWhoop 1 O O O I I O 108 19 8 420Hz 0 625s ON 0 625s OFF Australia AS1670 Alert tone 1 O O O I I I 102 10 9 500 1200Hz 0 5s 0 5s OFF x 3 1 5s OFF Australia AS1670 Evacuation tone 1 O O I O O O 106 13 10 550Hz 440Hz 0 5Hz 19 O O I O O I 104 21 11 970Hz 0 5s ON 0 5s OFF x 3 1 5s OFF ISO 8201 Low tone 1 O O I O I O 105 13 12 2850Hz 0 5s ON 0 5s OFF x 3 1 5s OFF ISO 8201 High tone 1 O O I O I I 107 16 13 1200Hz 500Hz 1Hz DIN 33 404 1 O O I I O O 109 22 14 400Hz 18 O O I I O I 101 16 15 550Hz 0 7s 1000Hz 0 33s 1 O O I I I O 105 25 16 1500Hz 2700Hz 3Hz Vandal Alarm 1 O O I I I I 113 32 17 Simulated Bell 1 O I O O O O 107 18 18 840Hz 1 O I O O O I 110 26 19 660Hz 10 O I O O I O 102 25 20 660Hz 1 8s ON 1 8s OFF 19 O I O O I I 102 14 21 660Hz 0 15s ON 0 15s OFF 19 O I O I O O 102 14 22 510Hz 0 25s 610Hz 0 25s 1 O I O I O I 103 24 23 800 1000Hz 0 5s each 1Hz 1 O I O I I O 106 25 24 250Hz 1200Hz 12Hz 1 O I O I I I 101 23 25 500Hz 1200Hz 0 33Hz 1 O I I O O O 108 21 26 2400Hz 2900Hz 9Hz 1 O I I O O I 113 39 27 2400Hz 2900Hz 3Hz 1 O I I O I O 111 39 28 800Hz 970Hz 100Hz 1 O I I O I I 104 23 29 800Hz 970Hz 9Hz 1 O I I I O O 104 27 30 800Hz 970Hz 3Hz 1 O I I I O I 105 28 31 800Hz 0 25s ON 1s OFF 1 O I I I I O 103 8 32 500Hz 1200Hz 3 75s 0 25s OFF AS2220 18 O I I I I I 108 20 33 340Hz 1 I O O O O O 101 17 34 1000Hz 19 I O O O O I 106 25 35 1400Hz 1600Hz 1s 1600Hz 1400Hz 0 5s NF 48 265 1 I O O O I O 104 34 36 660Hz 6 5s ON 13s OFF 1 I O O O I I 102 9 37 1000Hz 2000Hz 1s each 1 I O O I O O 108 25 38 720Hz 0 7s ON 0 3s OFF 1 I O O I O I 104 16 39 970Hz 0 25s ON OFF 1 I O O I I O 105 17 40 2800Hz 1s ON OFF 1 I O O I I I 106 20 41 2800Hz 0 25s ON OFF 1 I O I O O O 106 19 42 2400 2900 2Hz 1 I O I O O I 113 38 43 Chime 554Hz 440Hz Single shot ding dong 1 I O I O I O 100 15 44 Chime 554Hz 440Hz Repeating ding dong 1 I O I O I I 102 15 45 Chime 970Hz 800Hz Single shot ding dong 1 I O I I O O 101 36 46 Chime 970Hz 800Hz Repeating ding dong 1 I O I I O I 100 36 47 Hooter Repeating 1 I O I I I O 102 13 48 Gentle alarm Tone 2 rises slowly to full volume over 30s 1 I O I I I I 105 28 49 Time Out Alarm As Tone 2 cuts off after 10 mins 1 I I O O O O 105 28 50 Time Out Alarm As Tone 2 cuts off after 2 mins 1 I I O O O I 105 28 51 750Hz 0 33s ON 0 51s OFF 1 I I O O I O 103 8 52 750Hz 0 51s ON 0 33s OFF 1 I I O O I I 103 15 53 550Hz 0 33s 1000Hz 0 7s 1 I I O I O O 106 25 54 600Hz 900Hz 0 9s 1 I I O I O I 104 31 55 660Hz 680Hz 0 9s 1 I I O I I O 101 28 56 670Hz 725Hz 0 9s 1 I I O I I I 104 25 57 920Hz 750Hz 0 9s 1 I I I O O O 104 30 58 700Hz 900Hz 0 3s 0 6s OFF 1 I I I O O I 104 11 59 900Hz 760Hz 0 6s 0 3s OFF 1 I I I O I O 105 19 60 750Hz 18 I I I O I I 103 22 61 Power Only Use with Stage 3 control for manual intermittent chime triggering 43 I I I I O O 62 Power Only Use with Stage 3 control for manual intermittent chime triggering 43 I I I I O I 63 Power Only Use with Stage 3 control for manual intermittent horn triggering 47 I I I I I O 64 Reserved for future use I I I I I I

Vorschau Handbuch der Signalgeber - Einfach normgerecht alarmieren Seite 62
Hinweis: Dies ist eine maschinenlesbare No-Flash Ansicht.
Klicken Sie hier um zur Online-Version zu gelangen.